American Wire Group - 175 MIL TRXLP 15 KV URD Cable<br>One Third Neutral<br>Copper Conductor
 Search Catalog
      GO   
 All Categories    175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > 
Primary URD Cable
15KV-35KV
 > 175 MIL TRXLP 15 KV URD Cable
100% Insulation Level
 > 175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor

Check up to five results to perform an action.

URD Cable

larger image

Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% insulation level.  Suitable for either direct burial or installation in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
  • Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
  • Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 9 of 9 1 

    Item #

    Code Name

    Conductor Size AWG

    Conductor Stranding

    Copper Neutral No. of Wires

    Copper Neutral Size AWG

    Diameters Conductor

    Diameter Over Insulation

    Diameter Over Insulation Shield

    Diameter Over Neutral Wires

    Diameter Over Embedded Jacket

    Total w/o Jacket Weight

    Total w/ Embedded Jacket Weight

    Ampacity 3/C Direct Buried

    Ampacity 3/C Triplex Buried

    Ampacity 3/C Duct In Air

    Conductor
    Type

    Max. Conductor Temp. (Normal Continuous)

    Max. Conductor Temp. (Overload)

    Max. Conductor Temp. (Short Circuit)

    175-TRXLP-26 N/A 1/0 19 9 14 0.362 Inches 0.770 Inches 0.850 Inches 0.978 Inches 1.078 Inches 708 Lbs 777 Lbs 290 Amps 210 Amps 185 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-27 N/A 2/0 19 11 14 0.405 Inches 0.815 Inches 0.899 Inches 1.023 Inches 1.123 Inches 836 Lbs 907 Lbs 320 Amps 240 Amps 210 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-28 N/A 3/0 19 14 14 0.456 Inches 0.865 Inches 0.945 Inches 1.073 Inches 1.173 Inches 1002 Lbs 1074 Lbs 350 Amps 275 Amps 241 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-29 Holbein 4/0 19 11 12 0.512 Inches 0.920 Inches 1.000 Inches 1.162 Inches 1.262 Inches 1227 Lbs 1317 Lbs 390 Amps 315 Amps 276 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-30 Moreau 250 37 13 12 0.558 Inches 0.980 Inches 1.060 Inches 1.222 Inches 1.322 Inches 1427 Lbs 1546 Lbs 415 Amps 340 Amps 298 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-31 McNeil 350 37 12 10 0.660 Inches 1.080 Inches 1.200 Inches 1.404 Inches 1.504 Inches 1904 Lbs 2055 Lbs 475 Amps 415 Amps 364 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-32 Daumier 500 37 17 10 0.789 Inches 1.210 Inches 1.330 Inches 1.534 Inches 1.694 Inches 2664 Lbs 2823 Lbs 525 Amps 480 Amps 420 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-33 N/A 750 61 25 10 0.968 Inches 1.400 Inches 1.520 Inches 1.724 Inches 1.884 Inches 3794 Lbs 3964 Lbs 560 Amps 530 Amps 465 Amps Copper 90 oC 130 oC 250 oC
    175-TRXLP-34 N/A 1000 61 33 10 1.117 Inches 1.545 Inches 1.705 Inches 1.945 Inches 2.106 Inches 4948 Lbs 5127 Lbs 600 Amps 590 Amps 518 Amps Copper 90 oC 130 oC 250 oC
      Results 1 - 9 of 9 1