American Wire Group - 175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Aluminum Conductor
Search Catalog
By Keyword
By Item #
All Categories
175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Aluminum Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Primary URD Cable
15KV-35KV
>
175 MIL TRXLP 15 KV URD Cable
100% Insulation Level
>
175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Aluminum Conductor
>
View Items
Download PDF
Email This Page
Save To Favorites
175 MIL TRXLP 15 KV URD Cable
One Third Neutral
Aluminum Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 10 of 10
1
Item #
Code Name
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 3/C Direct Buried
Ampacity 3/C Triplex Buried
Ampacity 3/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
175-TRXLP-10
Gable
1/0
Solid
6
14
0.325 Inches
0.735 Inches
0.815 Inches
0.943 Inches
1.043 Inches
356 Lbs
460 Lbs
230 Amps
165 Amps
145 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-11
N/A
1/0
19
6
14
0.362 Inches
0.770 Inches
0.850 Inches
0.978 Inches
1.078 Inches
373 Lbs
515 Lbs
230 Amps
165 Amps
145 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-12
N/A
2/0
19
7
14
0.405 Inches
0.815 Inches
0.895 Inches
1.023 Inches
1.123 Inches
434 Lbs
575 Lbs
250 Amps
190 Amps
167 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-13
N/A
3/0
19
9
14
0.456 Inches
0.865 Inches
0.945 Inches
1.073 Inches
1.173 Inches
510 Lbs
655 Lbs
280 Amps
215 Amps
189 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-14
N/A
4/0
19
11
14
0.512 Inches
0.920 Inches
1.000 Inches
1.128 Inches
1.228 Inches
598 Lbs
759 Lbs
320 Amps
245 Amps
215 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-15
Degas
250
37
13
14
0.558 Inches
0.980 Inches
1.060 Inches
1.188 Inches
1.288 Inches
684 Lbs
889 Lbs
345 Amps
270 Amps
237 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-16
Hals
350
37
11
12
0.660 Inches
1.080 Inches
1.200 Inches
1.362 Inches
1.462 Inches
913 Lbs
1175 Lbs
405 Amps
325 Amps
285 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-17
Bosch
500
37
16
12
0.789 Inches
1.210 Inches
1.330 Inches
1.492 Inches
1.562 Inches
1207 Lbs
1498 Lbs
460 Amps
385 Amps
338 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-18
Vernet
750
61
15
10
0.968 Inches
1.400 Inches
1.520 Inches
1.724 Inches
1.884 Inches
1685 Lbs
2057 Lbs
515 Amps
475 Amps
417 Amps
Aluminum
90
o
C
130
o
C
250
o
C
175-TRXLP-19
N/A
1000
61
20
10
1.117 Inches
1.545 Inches
1.705 Inches
1.909 Inches
2.069 Inches
2210 Lbs
2516 Lbs
565 Amps
540 Amps
475 Amps
Aluminum
90
o
C
130
o
C
250
o
C
Results 1 - 10 of 10