American Wire Group - 220 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor
Search Catalog
By Keyword
By Item #
All Categories
220 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Primary URD Cable
15KV-35KV
>
220 MIL TRXLP 15 KV URD Cable
133% Insulation Level
>
220 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor
>
View Items
Download PDF
Email This Page
Save To Favorites
220 MIL TRXLP 15 KV URD Cable
One Third Neutral
Copper Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 3/C Direct Buried
Ampacity 3/C Triplex Buried
Ampacity 3/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
220-TRXLP-26
1/0
19
9
14
0.362 Inches
0.860 Inches
0.940 Inches
1.068 Inches
1.168 Inches
767 Lbs
842 Lbs
290 Amps
210 Amps
185 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-27
2/0
19
11
14
0.405 Inches
0.905 Inches
0.985 Inches
1.113 Inches
1.213 Inches
897 Lbs
975 Lbs
320 Amps
240 Amps
210 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-28
3/0
19
14
14
0.456 Inches
0.955 Inches
1.035 Inches
1.163 Inches
1.263 Inches
1066 Lbs
1145 Lbs
350 Amps
275 Amps
241 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-29
4/0
19
11
12
0.512 Inches
1.010 Inches
1.090 Inches
1.294 Inches
1.394 Inches
1333 Lbs
1434 Lbs
390 Amps
315 Amps
276 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-30
250
37
13
12
0.558 Inches
1.070 Inches
1.190 Inches
1.352 Inches
1.452 Inches
1539 Lbs
1673 Lbs
415 Amps
340 Amps
298 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-31
350
37
12
10
0.660 Inches
1.170 Inches
1.290 Inches
1.494 Inches
1.654 Inches
1987 Lbs
2149 Lbs
475 Amps
415 Amps
364 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-32
500
37
17
10
0.789 Inches
1.300 Inches
1.420 Inches
1.624 Inches
1.784 Inches
2754 Lbs
2924 Lbs
525 Amps
480 Amps
420 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-33
750
61
25
10
0.968 Inches
1.490 Inches
1.610 Inches
1.814 Inches
1.974 Inches
3952 Lbs
4138 Lbs
560 Amps
530 Amps
465 Amps
Copper
90
o
C
130
o
C
250
o
C
220-TRXLP-34
1000
61
33
10
1.117 Inches
1.635 Inches
1.795 Inches
1.999 Inches
2.159 Inches
5061 Lbs
5251 Lbs
600 Amps
590 Amps
518 Amps
Copper
90
o
C
130
o
C
250
o
C
Results 1 - 9 of 9