260 MIL TRXLP 25 KV URD Cable
Full Neutral
Aluminum Conductor

Check up to five results to perform an action.

URD Cable

larger image

Applications
For use on single phase and three phase primary underground distribution systems operating at 25kV phase to phase at 100% insulation level.  Suitable for either direct burial or installation in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
  • Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
  • Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.





  • Request InformationCompare Items   Results per Page : 
      Results 1 - 7 of 7 1 

    Item #

    Code Name

    Conductor Size AWG

    Conductor Stranding

    Copper Neutral No. of Wires

    Copper Neutral Size AWG

    Diameters Conductor

    Diameter Over Insulation

    Diameter Over Insulation Shield

    Diameter Over Neutral Wires

    Diameter Over Embedded Jacket

    Total w/o Jacket Weight

    Total w/ Embedded Jacket Weight

    Ampacity 1/C Direct Buried

    Ampacity 1/C Duct Buried

    Ampacity 1/C Duct In Air

    Conductor
    Type

    Max. Conductor Temp. (Normal Continuous)

    Max. Conductor Temp. (Overload)

    Max. Conductor Temp. (Short Circuit)

    260-TRXLP-01 N/A 1 Solid 13 14 0.289 Inches 0.870 Inches 0.950 Inches 1.078 Inches 1.178 Inches 518 Lbs 671 Lbs 195 Amps 145 Amps 127 Amps Aluminum 90 oC 130 oC 250 oC
    260-TRXLP-02 Liszt 1 19 13 14 0.322 Inches 0.900 Inches 0.980 Inches 1.108 Inches 1.208 Inches 535 Lbs 687 Lbs 195 Amps 145 Amps 127 Amps Aluminum 90 oC 130 oC 250 oC
    260-TRXLP-03 N/A 1/0 Solid 16 14 0.325 Inches 0.905 Inches 0.989 Inches 1.117 Inches 1.217 Inches 590 Lbs 748 Lbs 220 Amps 165 Amps 145 Amps Aluminum 90 oC 130 oC 250 oC
    260-TRXLP-04 Verdi 1/0 19 16 14 0.362 Inches 0.940 Inches 1.022 Inches 1.150 Inches 1.250 Inches 614 Lbs 767 Lbs 220 Amps 165 Amps 145 Amps Aluminum 90 oC 130 oC 250 oC
    260-TRXLP-05 Ives 2/0 19 13 12 0.405 Inches 0.985 Inches 1.065 Inches 1.227 Inches 1.327 Inches 722 Lbs 905 Lbs 250 Amps 190 Amps 167 Amps Aluminum 90 oC 130 oC 250 oC
    260-TRXLP-06 Bach 3/0 19 16 12 0.456 Inches 1.035 Inches 1.155 Inches 1.317 Inches 1.417 Inches 875 Lbs 1065 Lbs 290 Amps 210 Amps 185 Amps Aluminum 90 oC 130 oC 250 oC
    260-TRXLP-07 Mozart 4/0 19 20 12 0.512 Inches 1.090 Inches 1.210 Inches 1.372 Inches 1.472 Inches 1025 Lbs 1241 Lbs 325 Amps 245 Amps 215 Amps Aluminum 90 oC 130 oC 250 oC
      Results 1 - 7 of 7 1