American Wire Group - 345 MIL TRXLP 35 KV URD Cable
One Third Neutral
Copper Conductor
Search Catalog
By Keyword
By Item #
All Categories
345 MIL TRXLP 35 KV URD Cable
One Third Neutral
Copper Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Primary URD Cable
15KV-35KV
>
345 MIL TRXLP 35 KV URD Cable
100% Insulation Level
>
345 MIL TRXLP 35 KV URD Cable
One Third Neutral
Copper Conductor
>
View Items
Download PDF
Email This Page
Save To Favorites
345 MIL TRXLP 35 KV URD Cable
One Third Neutral
Copper Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 35kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 3/C Direct Buried
Ampacity 3/C Triplex Buried
Ampacity 3/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
345-TRXLP-20
1/0
19
9
14
0.362 Inches
1.110 Inches
1.230 Inches
1.358 Inches
1.458 Inches
999 Lbs
1102 Lbs
270 Amps
215 Amps
189 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-21
2/0
19
11
14
0.405 Inches
1.155 Inches
1.275 Inches
1.403 Inches
1.503 Inches
1139 Lbs
1244 Lbs
305 Amps
240 Amps
211 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-22
3/0
19
14
14
0.456 Inches
1.205 Inches
1.325 Inches
1.453 Inches
1.613 Inches
1316 Lbs
1423 Lbs
340 Amps
280 Amps
246 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-23
4/0
19
11
12
0.512 Inches
1.260 Inches
1.380 Inches
1.542 Inches
1.702 Inches
1576 Lbs
1707 Lbs
380 Amps
315 Amps
276 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-24
250
37
13
12
0.558 Inches
1.335 Inches
1.455 Inches
1.617 Inches
1.777 Inches
1799 Lbs
1971 Lbs
405 Amps
340 Amps
298 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-25
350
37
12
10
0.660 Inches
1.435 Inches
1.555 Inches
1.759 Inches
1.919 Inches
2269 Lbs
2474 Lbs
460 Amps
400 Amps
350 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-26
500
37
17
10
0.789 Inches
1.565 Inches
1.725 Inches
1.929 Inches
2.089 Inches
3117 Lbs
3337 Lbs
520 Amps
470 Amps
412 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-27
750
61
25
10
0.968 Inches
1.755 Inches
1.915 Inches
2.119 Inches
2.279 Inches
4300 Lbs
4531 Lbs
567 Amps
550 Amps
483 Amps
Copper
90
o
C
130
o
C
250
o
C
345-TRXLP-28
1000
61
33
10
1.117 Inches
1.900 Inches
2.060 Inches
2.264 Inches
2.424 Inches
5435 Lbs
5671 Lbs
625 Amps
615 Amps
540 Amps
Copper
90
o
C
130
o
C
250
o
C
Results 1 - 9 of 9
1