American Wire Group - Underground Distribution Cables 35kV
TR-XLPE/LLDPE or EPR/LLDPE
Search Catalog
By Keyword
By Item #
All Categories
Underground Distribution Cables 35kV
TR-XLPE/LLDPE or EPR/LLDPE
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Wind Farm Power Cable
>
Collection System Cables
>
Medium Voltage Power
>
Underground Distribution Cables 35kV
TR-XLPE/LLDPE or EPR/LLDPE
>
View Items
Download PDF
Email This Page
Save To Favorites
Underground Distribution Cables 35kV
TR-XLPE/LLDPE or EPR/LLDPE
Check up to five results to perform an action.
larger image
Applications
Intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried.
Construction
Crosslinked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over an aluminum conductor in a single operation. Helically applied, solid bare copper wires and black extruded jacket with a red stripe are applied over the cable core. The completed cable is a water-blocked construction, which includes a double water-blocked conductor and cable core/jacket tested in accordance with ICEA T-34-664. Solid or Class B compressed concentric lay stranded 1350 aluminum conductor meeting the requirements of ANSI/ICEA S-94-649. Conductor Shield is extruded semi-conducting thermosetting polymeric stress control layer. Extruded,unfilledTree-Retardant Crosslinked Polyethylene (TRXLPE) insulation as defined in ANSI/ICEA S-94-649-100% insulation level. Insulation Shield is extruded semi-conducting thermosetting layer, clean- and free-stripping from insulation. Concentric Neutral is helically applied annealed solid bare copper wires. Jacket is black, non-conducting, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires and extruded with red stripe. Insulation Temperature Rating: Normal 90°C; Emergency* 130°C; Short Circuit 250°C. These cables meet the latest requirements of ANSI/ICEA S-94-649, AEIC CS8 and ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable.
*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable.
Options:
EPR insulated cable; Copper conductors; Super-smooth semi-conducting conductor shield; Overall LLDPE jacket; 3X 1/C triplex or parallel; CSA certified
Results per Page :
25
50
100
200
Results 1 - 34 of 34
1
Item #
Size
AWG
Conductor
Diameter
(Inches)
Strand
No. of
Wires
Neutral Size
No. of
Neutral
Wires
and
Size
AWG
Jacket
Thick-
ness
(mils)
Nominal
Insulation
O.D.
Nominal
Jacket
O.D.
Approx Weight
Alum. Cond.
(LB/MFT)
Approx Weight
CU Neutral Wires
(LB/MFT)
Approx Weight
Total
(LB/MFT)
Am-
pacity
Direct Burial
FLAT
Am-
pacity
Direct Burial
Trefoil
Am-
pacity
Buried
in
Ducts
345-TRXLP-29
1/0
0.362
19
Full
16x14
55
1.145
1.416
99
209
908
232
217
174
345-TRXLP-30
1/0
0.362
19
2/3
11x14
55
1.145
1.416
99
144
850
233
217
174
345-TRXLP-31
1/0
0.362
19
1/2
8x14
55
1.145
1.416
99
104
815
234
217
174
345-TRXLP-32
1/0
0.362
19
1/3
6x14
55
1.145
1.416
99
78
792
235
217
174
345-TRXLP-33
3/0
0.456
19
Full
16x12
55
1.140
1.544
157
332
1182
300
286
229
345-TRXLP-34
3/0
0.456
19
2/3
17x14
55
1.140
1.513
157
222
1049
303
286
229
345-TRXLP-35
3/0
0.456
19
1/2
13x14
55
1.140
1.513
157
170
1002
305
286
229
345-TRXLP-36
3/0
0.456
19
1/3
9x14
55
1.140
1.513
157
118
995
307
286
229
345-TRXLP-37
4/0
0.512
19
Full
20x12
55
1.295
1.600
198
415
1340
339
328
262
345-TRXLP-38
4/0
0.512
19
2/3
21x14
55
1.295
1.569
198
274
1178
343
328
262
345-TRXLP-39
4/0
0.512
19
1/2
16x14
55
1.295
1.569
198
209
1120
346
329
262
345-TRXLP-40
4/0
0.512
19
1/3
11x14
55
1.295
1.569
198
144
1062
350
329
263
345-TRXLP-41
350
0.661
37
2/3
22x12
80
1.455
1.812
328
458
1695
428
431
352
345-TRXLP-42
350
0.661
37
1/2
17x12
80
1.455
1.812
328
354
1603
434
433
353
345-TRXLP-43
350
0.661
37
1/3
18x14
80
1.455
1.793
328
235
1457
445
436
354
345-TRXLP-44
350
0.661
37
1/6
9x14
80
1.455
1.793
328
117
1358
460
436
356
345-TRXLP-45
500
0.79
37
2/3
20x10
80
1.580
1.985
469
662
2181
496
523
427
345-TRXLP-46
500
0.79
37
1/2
24x12
80
1.580
1.942
469
498
1983
500
526
428
345-TRXLP-47
500
0.79
37
1/3
16x12
80
1.580
1.942
469
332
1834
516
531
432
345-TRXLP-48
500
0.79
37
1/6
13x14
80
1.580
1.909
469
170
1646
546
534
435
345-TRXLP-49
750
0.968
61
1/2
23x10
80
1.770
2.199
703
761
2727
572
631
532
345-TRXLP-50
750
0.968
61
1/3
24x12
80
1.770
2.157
703
498
2434
581
640
539
345-TRXLP-51
750
0.968
61
1/6
19x14
80
1.770
2.124
703
248
2163
626
651
548
345-TRXLP-52
750
0.968
61
1/12
10x14
80
1.770
2.124
703
131
2046
698
775
653
345-TRXLP-53
1000
1.117
61
1/2
30x10
80
1.920
2.363
937
993
3311
639
724
609
345-TRXLP-54
1000
1.117
61
1/3
20x10
80
1.920
2.363
937
660
3015
641
741
624
345-TRXLP-55
1000
1.117
61
1/6
16x12
80
1.920
2.306
937
332
2658
685
761
642
345-TRXLP-56
1000
1.117
61
1/12
13x14
80
1.920
2.273
937
170
2496
766
845
716
345-TRXLP-57
1250
1.25
91
1/3
25x10
80
2.065
2.505
1173
827
3467
664
817
687
345-TRXLP-58
1250
1.25
91
1/6
20x12
80
2.065
2.463
1173
415
3032
701
849
715
345-TRXLP-59
1250
1.25
91
1/12
16x14
80
2.065
2.430
1173
209
3794
784
870
733
345-TRXLP-60
1500
1.37
91
1/3
24x9
80
2.205
2.670
1408
1002
4036
702
868
730
345-TRXLP-61
1500
1.37
91
1/6
24x12
80
2.205
2.603
1408
497
3474
722
910
767
345-TRXLP-62
1500
1.37
91
1/12
19x14
80
2.205
2.570
1408
248
3193
813
940
793
Results 1 - 34 of 34