American Wire Group - Covered Line Wire Alloy 6201-T81<br>Aluminum Conductor
 Search Catalog
      GO   
 All Categories    Covered Line Wire Alloy 6201-T81
Aluminum Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Copper Building Wire > THHN/THWN-2 Copper Conductor
600 Volts, 90oC Dry or 75oC Wet
 > IMSA 50-2
Loop Detector Lead-In Wire
 > 
Single Conductor
600 V Secondary Type UD Cable
Aluminum Conductor
 > Mobile Home Feeder - Aluminum Conductor > Covered Line Wire ACSR
Aluminum Conductor
 > Type TFFN/TFN Copper Conductor
600 Volts 90oC Dry Locations
 > Ground Rod Accessories - Driving Studs > XHHW-2 XLP Copper Conductor
600 Volts, 90oC Wet or Dry
 > USE-2 / RHH / RHW-2
Copper Conductor
600 Volts, 90oC Wet or Dry
 > IMSA 51-1 THHN
Loop Detector Lead-In Wire
 > IMSA 51-3
Loop Detector Wire
 > IMSA 51-5
Tube Loop Detector Cable
 > ACSS Aluminum Conductor
Steel Supported
 > Ground Rod Accessories - Clamps > Ground Rod Accessories - Couplings > Covered Line Wire AAC
Aluminum Conductor
 > Covered Line Wire Alloy 6201-T81
Aluminum Conductor
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

Covered Line Wire Alloy 6201-T81
Aluminum Conductor

Check up to five results to perform an action.

Covered Line Wire

larger image
Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).

Standards
  • ASTM B-230 - Aluminum 1350-H19 Wire for Electrical Purposes
  • ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
  • ASTM B-1248 - Polyethylene Plastics Molding and Extrusion Materials.
  • ASTM C-8.35 - Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.
  • ICEAS-61-402
  • NEMA PUB NO. WC 5-1973 - Standards Publication Thermoplastic insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.


  • Notes
  • The code words as given apply to conventional polyethylene line wire.
  • For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.
  • Ampacity ratings based on 75oC conductor temperature, 25oC ambient temperature elevation – sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375oC-Cm2/Watt-CM. Wind speed 2ft/sec in sun.
  • To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 6 of 6 1 

    Item #

    Size AWG or MCM

    Strand

    Insulation Thickness

    Outside Diameter

    Rated Breaking Strength

    Weight Per 1000ft - XLP

    Weight Per 1000ft - Poly

    Ampacity - XLP

    Hornbeam 4 7/w 30 mls .310 Inches 1480 Lbs 62.1 Lbs 60.1 Lbs 145 Amps
    Linden 2 7/w 45 mls .406 Inches 2520 Lbs 96.1 Lbs 93.3 Lbs 190 Amps
    Oilnut 1/0 7/w 60 mls .518 Inches 4010 Lbs 166.1 Lbs 160.0 Lbs 250 Amps
    Waterash 2/0 7/w 60 mls .567 Inches 4850 Lbs 203.3 Lbs 196.4 Lbs 290 Amps
    Shellbark 3/0 7/w 60 mls .622 Inches 6110 Lbs 249.4 Lbs 241.4 Lbs 335 Amps
    Planetree 4/0 7/w 60 mls .683 Inches 7700 Lbs 307.3 Lbs 298.1 Lbs 385 Amps
      Results 1 - 6 of 6 1