American Wire Group - <br>Single Conductor<br>600 V Secondary Type UD Cable<br>Aluminum Conductor
 Search Catalog
      GO   
 All Categories    
Single Conductor
600 V Secondary Type UD Cable
Aluminum Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Aluminum Building Wire > Single Conductor Type UD Cable
Aluminum Conductor
 > 
Single Conductor
600 V Secondary Type UD Cable
Aluminum Conductor
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites


Single Conductor
600 V Secondary Type UD Cable
Aluminum Conductor

Check up to five results to perform an action.

Single Conductor 600 volt

larger image
Applications
Directly buried or installed in ducts for 600 volt secondary distribution.

Construction
Concentric stranded or compressed 1350-H19 aluminum conductor, crosslinked polyethylene insulation.

Standards
Secondary UD single conductor 600V cable meets or exceeds the following ASTM specifications.
  • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
  • B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
  • B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
  • Secondary UD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  • "USE-2" per UL 854 available upon request.

    Options
  • Cable in Duct (CIC)
  • Abrasion Resistant


  • Ampacity
    90oC conductor temperature, 20oC ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.




    Request InformationCompare Items   Results per Page : 
      Results 1 - 16 of 16 1 

    Item #

    Size AWG or MCM

    Stranding

    Insulation Thickness

    Outside Diameter

    Weight Per 1000ft

    Ampacity Direct Burial

    Ampacity In Duct

    Princeton 6 7/W 60 mls .298 Inches 45 Lbs 90 Amps 65 Amps
    Mercer 4 7/W 60 mls .345 Inches 64 Lbs 120 Amps 85 Amps
    Clemson 2 7/W 60 mls .403 Inches 93 Lbs 155 Amps 115 Amps
    Kenyon 1 19/W 80 mls .522 Inches 148 Lbs 200 Amps 150 Amps
    Harvard 1/0 19/W 80 mls .482 Inches 122 Lbs 175 Amps 130 Amps
    Yale 2/0 19/W 80 mls .566 Inches 179 Lbs 225 Amps 170 Amps
    Tufts 3/0 19/W 80 mls .616 Inches 217 Lbs 250 Amps 195 Amps
    Beloit 4/0 19/W 80 mls .672 Inches 265 Lbs 290 Amps 225 Amps
    Hofstra 250 37/W 95 mls .748 Inches 317 Lbs 320 Amps 250 Amps
    Gonzaga 300 37/W 95 mls .801 Inches 371 Lbs 355 Amps 280 Amps
    Rutgers 350 37/W 95 mls .851 Inches 423 Lbs 385 Amps 305 Amps
    Emory 500 37/W 95 mls .979 Inches 579 Lbs 465 Amps 370 Amps
    Duke 600 61/W 110 mls 1.086 Inches 701 Lbs 510 Amps 410 Amps
    Furman 700 61/W 110 mls 1.155 Inches 804 Lbs 550 Amps 440 Amps
    Sewanee 750 61/W 110 mls 1.188 Inches 855 Lbs 580 Amps 470 Amps
    Fordham 1000 61/W 110 mls 1.337 Inches 1109 Lbs 670 Amps 545 Amps
      Results 1 - 16 of 16 1