American Wire Group - Welding Cable - 600 Volt ICEA Approved - 105<SUP>o</SUP>C -40<SUP>o</SUP>C
 Search Catalog
      GO   
 All Categories    Welding Cable - 600 Volt ICEA Approved - 105oC -40oC
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Portable Power Cable
Welding Cable
Diesel Locomotive Wiring
Jumper Cable, Type W, G, G-GC
 > Welding Cable
600 Volts
 > Welding Cable - 600 Volt ICEA Approved - 105oC -40oC > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

Welding Cable - 600 Volt ICEA Approved - 105oC -40oC

Check up to five results to perform an action.

welding cable CHART

larger image

Click IMAGE to view WELDING MACHINE RATINGS Chart

Applications
Designed for Connections from electrode holders and clamps to arc welders, bus welding box or transformer

Recommended for use in shipyards, mines, and other areas where cable is subject to extreme physical abuse. Flame retardant, oil resistant, resilient, resists compression cuts and abrasion, durable handling.

This cable is not suitable for in line voltage use. Improper use could be hazardous to personnel and could damage equipment.

Construction
  • Conductor is annealed rope stranded bare copper conductor per ICEA S-75-381.
  • Insulation is Ethylene Propylene Rubber (EPR) type EP, Class 45, 105 C. Table 50.55 of UL.1581.
  • Separator between conductor and jacket is crepe paper.
  • Voltage is 600 Volts spark tested.

    Standards
    Meets ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.

    Available on Request
  • Class M stranding
  • Colors
  • Hypalon or Neoprene Insulation
  • UL or CSA Listed
  • Custom Cut Lengths

    Notes
  • Nominal resistance of conductor acc to ICEA S-75-381 Class K




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 11 of 11 1 

    Item #

    Size
    AWG

    Nominal Stranding Class K

    Nominal Resistance of Conductor at 25°C Ω/1000 Ft.

    Nominal Thickness of Insulation (Inches)

    Nominal
    O.D.
    (Inches)

    Copper Content Lbs./1000 Ft.

    Weight
    Per MFT

    W01-6 6 285/30 0.4190 0.059 0.319 83 120 Lbs
    W02-4 4 412/30 0.2630 0.059 0.366 133 180 Lbs
    W03-2 2 647/30 0.1670 0.071 0.429 213 260 Lbs
    W04-1 1 817/30 0.1330 0.071 0.508 266 320 Lbs
    W05-1/0 1/0 1021/30 0.1050 0.079 0.555 342 400 Lbs
    W06-2/0 2/0 1289/30 0.0842 0.079 0.598 433 500 Lbs
    W07-3/0 3/0 1650/30 0.0668 0.079 0.673 538 610 Lbs
    W08-4/0 4/0 2065/30 0.0530 0.079 0.716 687 760 Lbs
    W09-250 250MCM 2479/30 N/A 0.125 0.866 804 855 Lbs
    W10-350 350MCM 3416/30 N/A 0.125 0.953 1120 1255 Lbs
    W11-500 500MCM 4921/30 N/A 0.125 1.130 1638 1800 Lbs
      Results 1 - 11 of 11 1