American Wire Group - Type MP-GC 3-Conductor<br>EPR/CPE or XLP/CPE 8KV<br>100% Insul. Level (Grounded) 90<SUP>o</SUP>C
 Search Catalog
      GO   
 All Categories    Type MP-GC 3-Conductor
EPR/CPE or XLP/CPE 8KV
100% Insul. Level (Grounded) 90oC
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Mining Cable
Type W, G, G-GC, SHD-GC, MP-GG
 > Mine Power Feeder
Type MP-GC
 > Type MP-GC 3-Conductor
EPR/CPE or XLP/CPE 8KV
100% Insul. Level (Grounded) 90oC
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

Type MP-GC 3-Conductor
EPR/CPE or XLP/CPE 8KV
100% Insul. Level (Grounded) 90oC

Check up to five results to perform an action.

Mine Power Feeder

larger image

Applications
This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service.

Construction
  • Conductor is stranded annealed copper enveloped in a strand shield.
  • Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE).
  • Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round.
  • A single faced rubber filled tape is applied overlapped.
  • Jacket is Chlorinated Polyethylene (CPE).

    Standards
    Conforms to ICEA S-66-524 (NEMA WC8).

    Notes
    Shipping tolerance +/- 10%




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 9 of 9 1 

    Item #

    Power Conductors - Size AWG

    Power Conductors
    # of Strands

    Power Conductors
    Insulation Thickness

    Ground Wire - Size AWG

    Ground Wire - No. of Strands

    Jacket Thickness (Inches)

    Overall
    Diameter
    (inches)

    Net Weight Per 1000 ft.

    MP8-01-4 4 7 0.115 Inches 8 7 0.11 1.43 1440 Lbs
    MP8-02-2 2 7 0.115 Inches 6 7 0.11 1.55 1760 Lbs
    MP8-03-1 1 19 0.115 Inches 5 7 0.11 1.65 2070 Lbs
    MP8-04-1/0 1/0 19 0.115 Inches 4 7 0.11 1.75 2440 Lbs
    MP8-05-2/0 2/0 19 0.115 Inches 3 7 0.14 1.88 2940 Lbs
    MP8-06-4/0 4/0 19 0.115 Inches 1/0 19 0.14 2.12 4130 Lbs
    MP8-07-250 250 37 0.115 Inches 2/0 19 0.14 2.25 4760 Lbs
    MP8-08-350 350 37 0.115 Inches 3/0 19 0.14 2.46 6090 Lbs
    MP8-09-500 500 37 0.115 Inches 4/0 19 0.14 2.75 8360 Lbs
      Results 1 - 9 of 9 1