Applications
Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Construction
Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP).
Standards
ASTM B-230 - Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
ASTM B-1248 - Polyethylene Plastics Molding and Extrusion Materials.
ASTM C-8.35 - Specifications for Weather-Resistant Polethylene-Covered Wire and Cable.
ICEAS-61-402
NEMA PUB NO. WC 5-1973 - Standards Publication Thermoplastic insulated Wire and Cable for the Transmission and Distribution of Electrical Energy.
Notes
The code words as given apply to conventional polyethylene line wire.
For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent.
Ampacity ratings based on 75
o
C conductor temperature, 25
o
C ambient temperature elevation – sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375
o
C-Cm2/Watt-CM. Wind speed 2ft/sec in sun.
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Results per Page :
25
50
100
200
Results 1 - 11 of 11
1
Item #
Size AWG or MCM
Strand
Insulation Thickness
Outside Diameter
Rated Breaking Strength
Weight Per 1000ft - XLP
Weight Per 1000ft - Poly
Ampacity - XLP
Walnut
6
6/1
30 mls
.258 Inches
1131 Lbs
49 Lbs
47 Lbs
105 Amps
Butternut
4
6/1
30 mls
.303 Inches
1170 Lbs
71.8 Lbs
70.0 Lbs
135 Amps
Hickory
4
7/1
30 mls
.309 Inches
2240 Lbs
81.6 Lbs
79.8 Lbs
135 Amps
Pignut
2
6/1
45 mls
.397 Inches
2710 Lbs
118.1 Lbs
114.8 Lbs
180 Amps
Beech
2
7/1
45 mls
.405 Inches
3460 Lbs
134.1 Lbs
130.7 Lbs
180 Amps
Chestnut
1
6/1
45 mls
.434 Inches
3370 Lbs
145.5 Lbs
141.8 Lbs
210 Amps
Almond
1/0
6/1
60 mls
.506 Inches
4160 Lbs
190.4 Lbs
184.9 Lbs
235 Amps
Pecan
2/0
6/1
60 mls
.554 Inches
5040 Lbs
234.2 Lbs
227.9 Lbs
270 Amps
Filbert
3/0
6/1
60 mls
.607 Inches
6290 Lbs
288.5 Lbs
281.4 Lbs
305 Amps
Buckeye
4/0
6/1
60 mls
.666 Inches
7930 Lbs
356.5 Lbs
348.5 Lbs
345 Amps
Hackberry
266.8
18/1
60 mls
.711 Inches
6540 Lbs
354.8 Lbs
346.8 Lbs
435 Amps
Results 1 - 11 of 11