    15kV Type MV-105 Power Cable
    175 Mils EPR 100% Insulation
    With PVC Jacket
  • Bare Copper Tape Shield
  • Check up to five results to perform an action.

    mv105_copper_sun_resist_15000_100_insul

    larger image

    Applications
    For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105 deg. C, at not more than 140 deg. C. for emergency overload conditions and 250 deg. C during short-circuits. Suitable for systems rated 15 kV, 100% insulation level (grounded systems).

    Construction
    Copper concentrically stranded compressed conductor; triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; bare copper tape shielded; surface printed black PVC jacket.

    Standards
    1) Listed by Underwriters Laboratories as Type MV-105, as per UL Standard 1072. Sizes 4/0 AWG and larger are listed for CT use.
    2) Conforms to NEMA WC74/ICEA S-93-639 Standard for Shielded Power Cables Rated 5,000 – 46,000 Volts for the Transmission and Distribution of Electrical Energy.

    Notes

  • Ampacities are based on the NEC.
  • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105oC conductor, at an ambient temperature of 40oC.
  • Buried Duct: Three cables per duct operating at 105oC conductor, 20oC ground ambient, earth  ρ =  90, 100% load factor.
  • Conduit in Air: Three cables per isolated conduit in air at 40oC; operating at 105oC conductor (NEC Table 310.73).
  • CPE or CSPE Jacket available.




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 10 of 10 1 

    Item #

    Size AWG or KCM

    Stranding

    Insulation Thickness
    (mls)

    Jacket Thickness
    (mls)

    Diameter Over Insulation

    Diameter Over Insulation Shield

    Diameter Overall

    Net Weight Per 1000 ft.

    Ampacity 1/C in Cable Tray

    Ampacity 1/C Conduit In Air

    Ampacity 1/C Duct Buried

    105-175E2 2 7 175 70 0.700 Inches 0.770 Inches 1.000 Inches 620 Lbs N/A 165 Amps 165 Amps
    105-175E1/0 1/0 19 175 70 0.780 Inches 0.860 Inches 1.050 Inches 780 Lbs 290 Amps 215 Amps 215 Amps
    105-175E2/0 2/0 19 175 70 0.820 Inches 0.900 Inches 1.090 Inches 680 Lbs 335 Amps 245 Amps 255 Amps
    105-175E3/0 3/0 19 175 70 0.870 Inches 0.950 Inches 1.140 Inches 1000 Lbs 385 Amps 275 Amps 290 Amps
    105-175E4/0 4/0 19 175 70 0.930 Inches 1.010 Inches 1.200 Inches 1170 Lbs 445 Amps 315 Amps 330 Amps
    105-175E250 250 37 175 70 0.990 Inches 1.070 Inches 1.260 Inches 1320 Lbs 495 Amps 345 Amps 365 Amps
    105-175E350 350 37 175 70 1.090 Inches 1.190 Inches 1.380 Inches 1720 Lbs 610 Amps 415 Amps 440 Amps
    105-175E500 500 37 175 70 1.220 Inches 1.320 Inches 1.510 Inches 2270 Lbs 756 Amps 500 Amps 535 Amps
    105-175E750 750 61 175 100 1.410 Inches 1.510 Inches 1.700 Inches 3140 Lbs 990 Amps 610 Amps 655 Amps
    105-175E1000 1000 61 175 100 1.560 Inches 1.680 Inches 1.930 Inches 4170 Lbs 1185 Amps 690 Amps 755 Amps