    15kV Type MV-90 Power Cable
    175 Mils XLP 100% Insulation
    With PVC Jacket
  • Copper Tape Shielded
  • Check up to five results to perform an action.

    mv90_copper_tape_shield_15000_100_insul.jpg

    larger image

    Applications
    For installation in trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 90 deg. C, at not more than 130 deg. C. for emergency overload conditions and 250 deg. C during short-circuits. Suitable for systems rated 15 kV, 100% insulation level (grounded systems).

    Construction
    Copper concentrically stranded compressed conductor; triple single head extruded conductor shield, XLPE (cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; bare copper tape shield; surface printed black PVC jacket.

    Standards
    1) Listed by Underwriters Laboratories as Type MV-90, as per UL Standard 1072.
    2) Conforms to NEMA WC74/ICEA S-93-639 Standard for Shielded Power Cables Rated 5,000 – 46,000 Volts for the Transmission and Distribution of Electrical Energy.

    Notes

    ·  Ampacities are based on the NEC.

    ·  Buried Duct: Three cables per duct operating at 90oC conductor, 20oC ground ambient, earth ρ = 90, 100% load factor.

    ·  Conduit in Air: Three cables per isolated conduit in air at 40oC; operating at 90oC conductor.

  • CPE or CSPE Jacket available.

     





  • Request InformationCompare Items   Results per Page : 
      Results 1 - 10 of 10 1 

    Item #

    Size AWG or KCM

    Stranding

    Insulation Thickness
    (mls)

    Jacket Thickness
    (mls)

    Diameter Over Insulation

    Diameter Over Insulation Shield

    Diameter Overall

    Net Weight Per 1000 ft.

    Ampacity 1/C Duct Buried

    Ampacity 1/C Conduit In Air

    90-15X01T2 2 7 175 70 0.690 Inches 0.770 Inches 1.000 Inches 600 Lbs 155 Amps 150 Amps
    90-15XT021/0 1/0 19 175 70 0.780 Inches 0.860 Inches 1.050 Inches 750 Lbs 200 Amps 195 Amps
    90-15X03T2/0 2/0 19 175 70 0.820 Inches 0.900 Inches 1.090 Inches 850 Lbs 230 Amps 225 Amps
    90-15X04T3/0 3/0 19 175 70 0.870 Inches 0.950 Inches 1.140 Inches 980 Lbs 260 Amps 260 Amps
    90-15X05T4/0 4/0 19 175 70 0.930 Inches 1.010 Inches 1.200 Inches 1150 Lbs 295 Amps 295 Amps
    90-15X06T250 250 37 175 70 0.990 Inches 1.070 Inches 1.260 Inches 1300 Lbs 325 Amps 330 Amps
    90-15X07T350 350 37 175 70 1.090 Inches 1.190 Inches 1.380 Inches 1650 Lbs 390 Amps 395 Amps
    90-15X08T500 500 37 175 70 1.220 Inches 1.320 Inches 1.510 Inches 2170 Lbs 465 Amps 480 Amps
    90-15X09T750 750 61 175 100 1.410 Inches 1.510 Inches 1.700 Inches 3030 Lbs 565 Amps 585 Amps
    90-15X10T1000 1000 61 175 100 1.560 Inches 1.680 Inches 1.930 Inches 4030 Lbs 640 Amps 675 Amps