American Wire Group - 5kV/8kV Type MV-90 Power Cable<br>115 Mils XLP 133% Insulation<br>With PVC Jacket<br><LI>Copper Tape Shielded
 Search Catalog
      GO   
 All Categories    5kV/8kV Type MV-90 Power Cable
115 Mils XLP 133% Insulation
With PVC Jacket
  • Copper Tape Shielded
  • AWG CODE NAME FINDER
    Enter code name in the search field to the left for specific product information
    All Categories > Medium Voltage Cable
    MV90 & MV105, Airport Lighting
    5kV - 35kV
     > MV-90 Shielded (XLP) 5kV/8kV > 5kV/8kV Type MV-90 Power Cable
    115 Mils XLP 133% Insulation
    With PVC Jacket
  • Copper Tape Shielded > View Items 
  •     Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

    5kV/8kV Type MV-90 Power Cable
    115 Mils XLP 133% Insulation
    With PVC Jacket
  • Copper Tape Shielded
  • Check up to five results to perform an action.

    MV-90 115 Mils XLPE 5000/8000 Volt Power Cable, Copper Tape Shielded

    larger image

    Applications
    For installation in trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 90 deg. C, at not more than 130 deg. C. for emergency overload conditions and 250 deg. C during short-circuits. Suitable for systems rated 5 kV, 133% insulation level (ungrounded systems) or 8 kV, 100% insulation level (grounded systems).

    Construction
    Copper concentrically stranded compressed conductor; triple single head extruded conductor shield, XLPE (cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; bare copper tape shield; surface printed black PVC jacket.

    Standards
    1) Listed by Underwriters Laboratories as Type MV-90, as per UL Standard 1072.
    2) Conforms to NEMA WC74/ICEA S-93-639 Standard for Shielded Power Cables Rated 5,000 – 46,000 Volts for the Transmission and Distribution of Electrical Energy.

    Notes

  • Ampacities are based on the NEC.
  • Buried Duct: Three cables per duct operating at 90oC conductor, 20oC ground ambient, earth  ρ =  90, 100% load factor.
  • Conduit in Air: Three cables per isolated conduit in air at 40oC; operating at 90oC conductor.
  • CPE or CSPE Jacket available.




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 11 of 11 1 

    Item #

    Size AWG or KCM

    Stranding

    Minimum Point Insulation

    Minimum Point Jacket

    Diameter Over Insulation

    Diameter Over Insulation Shield

    Diameter Overall

    Net Weight Per 1000 ft.

    Ampacity 1/C Duct Buried

    Ampacity 1/C Conduit In Air

    90-5T2 2 7 115 mls 55 mls 0.550 Inches 0.640 Inches 0.940 Inches 500 Lbs 155 Amps 150 Amps
    90-5T1 1 19 115 mls 55 mls 0.590 Inches 0.680 Inches 0.980 Inches 570 Lbs 175 Amps 170 Amps
    90-5T1/0 1/0 19 115 mls 55 mls 0.640 Inches 0.720 Inches 1.020 Inches 660 Lbs 200 Amps 195 Amps
    90-5T2/0 2/0 19 115 mls 70 mls 0.690 Inches 0.770 Inches 1.060 Inches 760 Lbs 230 Amps 225 Amps
    90-5T3/0 3/0 19 115 mls 70 mls 0.740 Inches 0.820 Inches 1.100 Inches 900 Lbs 260 Amps 260 Amps
    90-5T4/0 4/0 19 115 mls 70 mls 0.800 Inches 0.870 Inches 1.180 Inches 1040 Lbs 295 Amps 295 Amps
    90-5T250 250 37 115 mls 70 mls 0.860 Inches 0.930 Inches 1.220 Inches 1200 Lbs 325 Amps 330 Amps
    90-5T350 350 37 115 mls 70 mls 0.960 Inches 1.030 Inches 1.340 Inches 1600 Lbs 390 Amps 395 Amps
    90-5T500 500 37 115 mls 70 mls 1.080 Inches 1.170 Inches 1.460 Inches 2060 Lbs 465 Amps 480 Amps
    90-5T750 750 61 115 mls 70 mls 1.270 Inches 1.360 Inches 1.650 Inches 2950 Lbs 565 Amps 585 Amps
    90-5T1000 1000 61 115 mls 70 mls 1.420 Inches 1.510 Inches 1.890 Inches 3850 Lbs 640 Amps 675 Amps
      Results 1 - 11 of 11 1