American Wire Group -
SOOW/SEOOW Cables
Search Catalog
By Keyword
By Item #
All Categories
SOOW/SEOOW Cables
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Wind Farm Power Cable
>
Tower Cables
>
Control
>
SOOW/SEOOW Cables
>
View Items
Download PDF
Email This Page
Save To Favorites
SOOW/SEOOW Cables
Check up to five results to perform an action.
larger image
Applications
Special uses requiring flexibility and mechanical toughness, high environmental resistance and flame retardance. Push button remote controls. Motor control, stage equipment and lighting. Industrial control and robotic systems. Outdoor applications. Suitable and approved for submersion in water.
Construction
Flexible and tough jacket. Offers -50°C to 105°C temperature extremes. Offers excellent abrasion, ozone, sunlight, chemical and oil resistance as well as water and mold resistant non-wicking lightweight polypropylene fillers. Water resistant with high dielectric insulation. Lightweight, long lasting, easy to carry and easy to handle. All components are recyclable and non-hazardous for environmental landfill disposal. Color coded conductors for easy identification.
Standards
Federal and Military use under Federal Spec. JC-580B. UL Listed SOOW/SEOOW 600V to NEC Article 400, MSHA approval for flame resistance for mining applications.
Color Code
2/C Black, White
3/C Black, White, Green
4/C Black, White, Red, Green
5/C Black, White, Red, Green, Orange
** Ampacity based on NEC Table 400-5(A) for sized 18/2 thru 10/4 and table 400-5 (B) for sizes 8/2 thru 2/5.
Note:
Sizes up to 10/4 are UL/CSA/MSHA, sizes 8/2 to 2/5 are non-UL constructions made with wall thicknesses in accordance with industry standards and MSHA approved.
The ampacity is provided for engineering information only. The manufacturer cannot recommend or express the use of these ampacities since the exact application may need approval from the authority having local jurisdiction. Above information is subject to engineering changes. Cold temperature rating is -50
°
C.
Results per Page :
25
50
100
200
Results 1 - 36 of 36
1
Part
Number
Size/Conductors
Strands
Nominal
O.D.
Weight
per/MFT
Amp
22225
18/2
16/30
0.345
61
10
22325
18/3
16/30
0.365
71
10
22425
18/4
16/30
0.39
84
7
30505
18/5
16/30
0.465
113
5.6
22226
16/2
26/30
0.37
74
13
22326
16/3
26/30
0.39
87
13
22426
16/4
26/30
0.415
103
10
30506
16/5
26/30
0.495
140
8
22227
14/2
41/30
0.5
129
18
22327
14/3
41/30
0.525
151
18
22427
14/4
41/30
0.565
180
15
30507
14/5
41/30
0.645
232
12
22228
12/2
65/30
0.57
173
25
22328
12/3
65/30
0.595
203
25
22428
12/4
65/30
0.645
247
20
30508
12/5
65/30
0.71
301
16
22229
10/2
104/30
0.62
218
30
22329
10/3
104/30
0.655
265
30
22429
10/4
104/30
0.705
324
25
30509
10/5
104/30
0.765
387
20
22220
8/2
96/28
0.662
220
40
22320
8/3
96/28
0.701
290
40
22420
8/4
96/28
0.783
377
35
22470
8/5
96/28
0.851
452
28
22221
6/2
96/26
0.752
301
55
22321
6/3
96/26
0.818
421
45
22421
6/4
96/26
0.892
521
45
22521
6/5
96/26
0.992
665
36
22222
4/2
96/24
0.892
459
70
22322
4/3
96/24
0.913
585
70
22422
4/4
96/24
1.027
771
60
22552
4/5
96/24
1.117
1029
48
22223
2/2
7x17/.0223
1.091
665
95
22323
2/3
7x17/.0223
1.158
940
95
22423
2/4
7x17/.0223
1.267
1170
80
22553
2/5
7x17/.0223
1.396
1419
64
Results 1 - 36 of 36
1