American Wire Group - <br>SOOW/SEOOW Cables
 Search Catalog
      GO   
 All Categories    
SOOW/SEOOW Cables
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Wind Farm Power Cable > Tower Cables > 
Control
 > 
SOOW/SEOOW Cables
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites


SOOW/SEOOW Cables

Check up to five results to perform an action.

SOOW

larger image
Applications
Special uses requiring flexibility and mechanical toughness, high environmental resistance and flame retardance. Push button remote controls. Motor control, stage equipment and lighting. Industrial control and robotic systems. Outdoor applications. Suitable and approved for submersion in water.

Construction
Flexible and tough jacket. Offers -50°C to 105°C temperature extremes. Offers excellent abrasion, ozone, sunlight, chemical and oil resistance as well as water and mold resistant non-wicking lightweight polypropylene fillers. Water resistant with high dielectric insulation. Lightweight, long lasting, easy to carry and easy to handle. All components are recyclable and non-hazardous for environmental landfill disposal. Color coded conductors for easy identification.

Standards
Federal and Military use under Federal Spec. JC-580B. UL Listed SOOW/SEOOW 600V to NEC Article 400, MSHA approval for flame resistance for mining applications.

Color Code
  • 2/C Black, White
  • 3/C Black, White, Green
  • 4/C Black, White, Red, Green
  • 5/C Black, White, Red, Green, Orange

    ** Ampacity based on NEC Table 400-5(A) for sized 18/2 thru 10/4 and table 400-5 (B) for sizes 8/2 thru 2/5.

    Note:
    Sizes up to 10/4 are UL/CSA/MSHA, sizes 8/2 to 2/5 are non-UL constructions made with wall thicknesses in accordance with industry standards and MSHA approved.
    The ampacity is provided for engineering information only. The manufacturer cannot recommend or express the use of these ampacities since the exact application may need approval from the authority having local jurisdiction. Above information is subject to engineering changes. Cold temperature rating is -50°C.


  • Search Items


    Request InformationCompare Items   Results per Page : 
      Results 1 - 36 of 36 1 

    Part
    Number

    Size/Conductors

    Strands

    Nominal
    O.D.

    Weight
    per/MFT

    Amp

    22225 18/2 16/30 0.345 61 10
    22325 18/3 16/30 0.365 71 10
    22425 18/4 16/30 0.39 84 7
    30505 18/5 16/30 0.465 113 5.6
    22226 16/2 26/30 0.37 74 13
    22326 16/3 26/30 0.39 87 13
    22426 16/4 26/30 0.415 103 10
    30506 16/5 26/30 0.495 140 8
    22227 14/2 41/30 0.5 129 18
    22327 14/3 41/30 0.525 151 18
    22427 14/4 41/30 0.565 180 15
    30507 14/5 41/30 0.645 232 12
    22228 12/2 65/30 0.57 173 25
    22328 12/3 65/30 0.595 203 25
    22428 12/4 65/30 0.645 247 20
    30508 12/5 65/30 0.71 301 16
    22229 10/2 104/30 0.62 218 30
    22329 10/3 104/30 0.655 265 30
    22429 10/4 104/30 0.705 324 25
    30509 10/5 104/30 0.765 387 20
    22220 8/2 96/28 0.662 220 40
    22320 8/3 96/28 0.701 290 40
    22420 8/4 96/28 0.783 377 35
    22470 8/5 96/28 0.851 452 28
    22221 6/2 96/26 0.752 301 55
    22321 6/3 96/26 0.818 421 45
    22421 6/4 96/26 0.892 521 45
    22521 6/5 96/26 0.992 665 36
    22222 4/2 96/24 0.892 459 70
    22322 4/3 96/24 0.913 585 70
    22422 4/4 96/24 1.027 771 60
    22552 4/5 96/24 1.117 1029 48
    22223 2/2 7x17/.0223 1.091 665 95
    22323 2/3 7x17/.0223 1.158 940 95
    22423 2/4 7x17/.0223 1.267 1170 80
    22553 2/5 7x17/.0223 1.396 1419 64
      Results 1 - 36 of 36 1