American Wire Group - Quadruplex Service Drop<br>Aluminum Conductors<br>AAAC 6201 Alloy Neutral-Messenger
 Search Catalog
      GO   
 All Categories    Quadruplex Service Drop
Aluminum Conductors
AAAC 6201 Alloy Neutral-Messenger
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Aluminum Service Drop Cable
Duplex, Triplex, Quadruplex
 > Quadruplex Service Drop Cable
Aluminum Conductor
 > Quadruplex Service Drop
Aluminum Conductors
AAAC 6201 Alloy Neutral-Messenger
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

Quadruplex Service Drop
Aluminum Conductors
AAAC 6201 Alloy Neutral-Messenger

Check up to five results to perform an action.

Quadruplex Service Drop

larger image
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Standards
  • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
  • B-231 Aluminum conductors, Concentric-Lay-Stranded.
  • B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
  • B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
  • B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
  • Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

    Note :
    Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.



  • Request InformationCompare Items   Results per Page : 
      Results 1 - 9 of 9 1 

    Item #

    Phase Conductor Size AWG

    Phase Conductor Stranding

    Phase Conductor Insulation Thickness

    Bare Neutral Messenger Size AWG

    Bare Neutral Messenger Stranding

    Bare Neutral messenger Breaking Strength

    Weight Per 1000ft - XLP

    Weight Per 1000ft - Poly

    Ampacity - XLP

    Ampacity - Poly

    Bay 6 Solid 45 mls 6 7 1110 Lbs 145 Lbs 140.0 Lbs 75 Amps 60 Amps
    French Coach 6 7/w 45 mls 6 7 1110 Lbs 155 Lbs 144.3 Lbs 75 Amps 60 Amps
    German Coach 4 Solid 45 mls 4 7 1760 Lbs 214 Lbs 208.3 Lbs 100 Amps 80 Amps
    Arabian 4 7/w 45 mls 4 7 1760 Lbs 229 Lbs 214.4 Lbs 100 Amps 80 Amps
    Belgian 2 7/w 45 mls 2 7 2800 Lbs 344 Lbs 323.1 Lbs 135 Amps 105 Amps
    Shetland 1/0 19/w 60 mls 1/0 7 4460 Lbs 546 Lbs 521.1 Lbs 180 Amps 140 Amps
    Thoroughbred 2/0 19/w 60 mls 2/0 7 5390 Lbs 670 Lbs 641.5 Lbs 205 Amps 160 Amps
    Trotter 3/0 19/w 60 mls 3/0 7 6790 Lbs 825 Lbs 791.8 Lbs 235 Amps 185 Amps
    Walking 4/0 19/w 60 mls 4/0 7 8560 Lbs 1019 Lbs 979.7 Lbs 275 Amps 210 Amps
      Results 1 - 9 of 9 1