Aluminum Service Drop Cable
Duplex, Triplex, Quadruplex
>
Quadruplex Service Drop Cable
Aluminum Conductor
>
Quadruplex Service Drop
Aluminum Conductors
AAAC 6201 Alloy Neutral-Messenger
>
View Items
Download PDF
Email This Page
Save To Favorites
Quadruplex Service Drop
Aluminum Conductors
AAAC 6201 Alloy Neutral-Messenger
Check up to five results to perform an action.
larger image
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Note :
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.
Results per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Phase Conductor Size AWG
Phase Conductor Stranding
Phase Conductor Insulation Thickness
Bare Neutral Messenger Size AWG
Bare Neutral Messenger Stranding
Bare Neutral messenger Breaking Strength
Weight Per 1000ft - XLP
Weight Per 1000ft - Poly
Ampacity - XLP
Ampacity - Poly
Bay
6
Solid
45 mls
6
7
1110 Lbs
145 Lbs
140.0 Lbs
75 Amps
60 Amps
French Coach
6
7/w
45 mls
6
7
1110 Lbs
155 Lbs
144.3 Lbs
75 Amps
60 Amps
German Coach
4
Solid
45 mls
4
7
1760 Lbs
214 Lbs
208.3 Lbs
100 Amps
80 Amps
Arabian
4
7/w
45 mls
4
7
1760 Lbs
229 Lbs
214.4 Lbs
100 Amps
80 Amps
Belgian
2
7/w
45 mls
2
7
2800 Lbs
344 Lbs
323.1 Lbs
135 Amps
105 Amps
Shetland
1/0
19/w
60 mls
1/0
7
4460 Lbs
546 Lbs
521.1 Lbs
180 Amps
140 Amps
Thoroughbred
2/0
19/w
60 mls
2/0
7
5390 Lbs
670 Lbs
641.5 Lbs
205 Amps
160 Amps
Trotter
3/0
19/w
60 mls
3/0
7
6790 Lbs
825 Lbs
791.8 Lbs
235 Amps
185 Amps
Walking
4/0
19/w
60 mls
4/0
7
8560 Lbs
1019 Lbs
979.7 Lbs
275 Amps
210 Amps