Mobile Home Feeder - Aluminum Conductor

Check up to five results to perform an action.

Quadruplex Conductor 600 volt

larger image
Application:
Mobile Home Feeder Cable is mainly used for supplying the energy required within the mobile home. The cable is designed for use at 600 volts or less and conductor temperatures not exceeding 90oC.

Construction:
Quadruplexed tye USE-2 or RHH or RHW-2 compact stranded AA-8000 Series aluminum alloy conductors. Insulation is sunlight-resistant Cross-linked Polyethylene (XLPE). Neutral is identified by triple extruded white stripes and Grounding is identified by total green surface coating.

Marking:
  • Manufacturer's ID plus E FILE NUMBER (SIZE AWG) AA-8000 AL TYPE USE-2 OR RHH OR RHW-2 SUN-RES 600V XLPE (UL) plus YEAR OF MANUFACTURE.
  • Sequential footage markings.

    Installation:
    Suitable for direct burial or underground installations and in raceways.

    Standards
    Mobile Home Feeder cable meets or exceeds the following specifications:
  • ASTM B800 and B801 or B836 as applicable.
  • UL 44
  • UL 854
  • NEC requirements.


  • To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.




    Request InformationCompare Items   Results per Page : 
      Results 1 - 6 of 6 1 

    Item #

    Phase Conductor Size AWG

    Phase Conductor Const.

    Phase Conductor Diameter

    Neutral Size AWG

    Neutral Conductor Const.

    Neutral Conductor Diameter

    Grounding Conductor Size AWG

    Grounding Conductor Const.

    Grounding Conductor Diameter

    Diameter Complete Cable (O.D.)

    Allowable Ampacity

    2-2-2-4 2 7 0.403 Inches 2 7 0.403 Inches 4 7 0.345 Inches 0.942 Inches 100 Amps
    2-5-4-6 2 7 0.403 Inches 4 7 0.345 Inches 6 7 0.298 Inches 0.938 Inches 100 Amps
    2/0-2/0-2/0-1 2/0 19 0.566 Inches 2/0 19 0.566 Inches 1 19 0.482 Inches 1.321 Inches 150 Amps
    2/0-2/0-4-1 2/0 19 0.566 Inches 1 19 0.482 Inches 4 7 0.345 Inches 1.210 Inches 150 Amps
    4/0-4/0-4/0-2/0 4/0 19 0.672 Inches 4/0 19 0.672 Inches 2/0 19 0.566 Inches 1.567 Inches 200 Amps
    4/0-4/0-2/0-4 4/0 19 0.672 Inches 2/0 19 0.566 Inches 4 7 0.345 Inches 1.480 Inches 200 Amps
      Results 1 - 6 of 6 1