American Wire Group - Quadruplex Conductor 600 V Secondary Type URD Cable
Aluminum Conductor
Search Catalog
By Keyword
By Item #
All Categories
Quadruplex Conductor 600 V Secondary Type URD Cable
Aluminum Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Secondary Aluminum
600 Volts URD
>
Quadruplex Conductor Type URD
Cable & Mobile Home Feeder
>
Quadruplex Conductor 600 V Secondary Type URD Cable
Aluminum Conductor
>
View Items
Download PDF
Email This Page
Save To Favorites
Quadruplex Conductor 600 V Secondary Type URD Cable
Aluminum Conductor
Check up to five results to perform an action.
larger image
Applications
Directly buried or installed in ducts for 600 volt secondary distribution.
Construction
Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yel low striped. Three phase and one neutral conductor cabled together (LH lay) or parallel if so specified. Black neutrals may be specified is desired.
Standards
Secondary UD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded.
B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation".
B-901 "Compressed round stranded Aluminum Conductors using single input wire construction".
Secondary UD quadruplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
"USE-2" per UL 854 available upon request.
Options
Cable in Duct (CIC)
Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
Results per Page :
25
50
100
200
Results 1 - 14 of 14
1
Item #
Phase Conductor Size AWG
Phase Conductor Stranding
Phase Conductor Insulation Thickness
Neutral Size AWG
Neutral Stranding
Neutral Insulation Thickness
Single Phase Conductor
Outside Diameter
Weight Per 1000ft
Ampacity Direct Burial
Ampacity In Duct
Tulsa
4
7
60 mls
4
4
60 mls
.345 Inches
.833 Inches
258 Lbs
119 Amps
85 Amps
Dyke
2
7
60 mls
4
4
60 mls
.403 Inches
.938 Inches
346 Lbs
153 Amps
115 Amps
Wittenberg
2
7
60 mls
2
2
60 mls
.403 Inches
.973 Inches
375 Lbs
153 Amps
115 Amps
Notre Dame
1/0
19
80 mls
2
2
60 mls
.522 Inches
1.188 Inches
541 Lbs
198 Amps
150 Amps
Purdue
1/0
19
80 mls
1/0
1/0
80 mls
.522 Inches
1.260 Inches
596 Lbs
198 Amps
150 Amps
Syracuse
2/0
19
80 mls
1
1
80 mls
.566 Inches
1.316 Inches
664 Lbs
225 Amps
170 Amps
Lafayette
2/0
19
80 mls
2/0
2/0
80 mls
.566 Inches
1.367 Inches
720 Lbs
225 Amps
170 Amps
Swarthmore
3/0
19
80 mls
1/0
1/0
80 mls
.616 Inches
1.430 Inches
805 Lbs
250 Amps
195 Amps
Davidson
3/0
19
80 mls
3/0
3/0
80 mls
.616 Inches
1.487 Inches
874 Lbs
250 Amps
195 Amps
Wake Forest
4/0
19
80 mls
2/0
2/0
80 mls
.672 Inches
1.560 Inches
979 Lbs
290 Amps
225 Amps
Earlham
4/0
19
80 mls
4/0
4/0
80 mls
.672 Inches
1.623 Inches
1066 Lbs
290 Amps
225 Amps
Slippery Rock
350
37
95 mls
4/0
4/0
80 mls
.851 Inches
1.945 Inches
1544 Lbs
385 Amps
305 Amps
Wofford
500
37
95 mls
350
350
95 mls
.851 Inches
2.348 Inches
2174 Lbs
467 Amps
420 Amps
Windham
750
61
110 mls
500
500
95 mls
.979 Inches
2.850 Inches
2542 Lbs
615 Amps
492 Amps
Results 1 - 14 of 14
1