American Wire Group - Thermocouple Cable
EX, JX, KX, TX
600V, 90
o
C Wet or Dry
Search Catalog
By Keyword
By Item #
All Categories
Thermocouple Cable
EX, JX, KX, TX
600V, 90
o
C Wet or Dry
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Thermocouple Cable
FREP/CPE - EX, JX, KX, TX
>
Thermocouple Cable
EX, JX, KX, TX
600V, 90
o
C Wet or Dry
>
View Items
Download PDF
Email This Page
Save To Favorites
Thermocouple Cable
EX, JX, KX, TX
600V, 90
o
C Wet or Dry
Check up to five results to perform an action.
larger image
Application:
For use as a 600 Volt, multi-pair thermocouple instrumentation cable where flame-retardance, and moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct burial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC).
Temperature rating of 90
o
C wet or dry. Insulation provides excellent electrical, thermal, and physical properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-40
o
C) cold bend characteristics.
Approved for direct burial.
Construction:
Conductor is thermocouple alloy per ANSI MC96.1 - 1982.
Extruded flame-retardant ethylene propylene rubber (EPR) insulation.
Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled together with fillers as needed to form a round core. An overall aluminum mylar shield and drain wire is applied over the core.
Pairs are color coded per thermocouple type with pair number printed on the negative (red) conductor. See chart below for specific color codes.
Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with color coded jacket.
Available with class B stranding per ASTM B174.
Standards:
Insulated Conductor - VW-1.
UL Type TC, 90
o
C Wet or Dry, 600V
ICEA S-82-552, 90
o
C Wet or Dry, 600V.
Passes UL 1277 Flame Test (70,000 BTU/hr).
Passes UL 1202 Flame Test (70,000 BTU/hr).
Passes IEEE 383 Flame Test (70,000 BTU/hr).
Passes ICEA T-29-520 Flame Test (210,000 BTU/hr).
EX - Color Code
Chromel (Positive) - PURPLE
Constantan (Negative) - RED
JX - Color Code
Iron (Positive) - WHITE
Constantan (Negative) - RED
TX - Color Code
Copper (Positive) - BLUE
Constantan (Negative) - RED
KX - Color Code
Chromel (Positive) - YELLOW
Alumel (Negative) - RED
Note:
Dimensions and weights shown are nominal, subject to industry tolerances. Dimensions and weights for other cabLe configurations are available upon request.
Results per Page :
25
50
100
200
Results 1 - 30 of 30
1
Item #
Size
AWG
Number of
Shielded Pairs
Insulation Thickness
(mils)
Jacket Thickness
(mls)
Overall
Diameter
(inches)
Weight
LBS/MFT
ITC-20-1
20
1
0.025
0.045
0.270
35
ITC-20-2
20
2
0.025
0.045
0.035
70
ITC-20-3
20
3
0.025
0.045
0.450
85
ITC-20-4
20
4
0.025
0.045
0.500
105
ITC-20-6
20
6
0.025
0.045
0.600
160
ITC-20-8
20
8
0.025
0.045
0.670
210
ITC-20-10
20
10
0.025
0.045
0.735
240
ITC-20-12
20
12
0.025
0.045
0.790
280
ITC-20-16
20
16
0.025
0.045
0.890
360
ITC-20-24
20
24
0.025
0.045
1.060
500
ITC-18-1
18
1
0.025
0.045
0.300
50
ITC-18-2
18
2
0.025
0.045
0.480
90
ITC-18-3
18
3
0.025
0.045
0.510
115
ITC-18-4
18
4
0.025
0.045
0.595
165
ITC-18-6
18
6
0.025
0.045
0.670
220
ITC-18-8
18
8
0.025
0.045
0.750
280
ITC-18-10
18
10
0.025
0.045
0.820
340
ITC-18-12
18
12
0.025
0.045
0.930
430
ITC-18-16
18
16
0.025
0.045
1.045
540
ITC-18-24
18
24
0.025
0.045
1.235
760
ITC-16-1
16
1
0.025
0.045
0.325
60
ITC-16-2
16
2
0.025
0.045
0.570
130
ITC-16-3
16
3
0.025
0.045
0.600
160
ITC-16-4
16
4
0.025
0.045
0.660
200
ITC-16-6
16
6
0.025
0.045
0.740
270
ITC-16-8
16
8
0.025
0.045
0.880
380
ITC-16-10
16
10
0.025
0.045
0.970
460
ITC-16-12
16
12
0.025
0.045
1.035
530
ITC-16-16
16
16
0.025
0.045
1.165
570
ITC-16-24
16
24
0.025
0.045
1.400
960
Results 1 - 30 of 30
1