American Wire Group - USE-2 / RHH / RHW-2 Direct Burial<br>Aluminum Conductor<br>600 Volts, 90<sup>o</sup>C Wet or Dry
 Search Catalog
      GO   
 All Categories    USE-2 / RHH / RHW-2 Direct Burial
Aluminum Conductor
600 Volts, 90oC Wet or Dry
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Aluminum Building Wire > 
Use-RHH-RHW-2 Direct Burial
Aluminum Conductor
 > USE-2 / RHH / RHW-2 Direct Burial
Aluminum Conductor
600 Volts, 90oC Wet or Dry
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

USE-2 / RHH / RHW-2 Direct Burial
Aluminum Conductor
600 Volts, 90oC Wet or Dry

Check up to five results to perform an action.

USE-RHH-RHW-2

larger image
Applications
Type USE-RHH-RHW-2 building wire and service cable is recognized for use as general purpose wiring at a maximum conductor temperature of 90°C in wet or dry locations for installation in air, conduit or other recognized raceways and for direct burial in circuits not exceeding 600 volts.

Construction
Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat, moisture and sunlight resistant crosslinked polyethylene insulation.

Standards
  • UL Standards 44 (RHW or RHH)
  • UL standard 854 (USE-2)
  • Federal specification JC-30B NEC
  • ASTM B800, B801, B836 as applicable.

    Ampacity
    To determine correct ampacity by conductor size, please consult the National Electric Code, Latest edition.




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 18 of 18 1 

    Item #

    Size AWG or MCM

    Stranding

    Insulation Thickness

    Outside Diameter

    Weight Per 1000ft

    Ampacity 90°C

    USE-RHH-RHW-2-0008 8 7/W 60 mls .266 Inches 37 Lbs 45 Amps
    USE-RHH-RHW-2-0006 6 7/W 60 mls .290 Inches 49 Lbs 60 Amps
    USE-RHH-RHW-2-0004 4 7/W 60 mls .334 Inches 65 Lbs 75 Amps
    USE-RHH-RHW-2-0002 2 7/W 60 mls .390 Inches 94 Lbs 100 Amps
    USE-RHH-RHW-2-0001 1 18/w 80 mls .460 Inches 125 Lbs 115 Amps
    USE-RHH-RHW-2-01/0 1/0 18/w 80 mls .500 Inches 150 Lbs 135 Amps
    USE-RHH-RHW-2-02/0 2/0 18/w 80 mls .540 Inches 181 Lbs 150 Amps
    USE-RHH-RHW-2-03/0 3/0 18/w 80 mls .590 Inches 220 Lbs 175 Amps
    USE-RHH-RHW-2-04/0 4/0 18/w 80 mls .635 Inches 268 Lbs 205 Amps
    USE-RHH-RHW-2-0250 250 35/w 95 mls .710 Inches 320 Lbs 230 Amps
    USE-RHH-RHW-2-0300 300 35/w 95 mls .760 Inches 374 Lbs 255 Amps
    USE-RHH-RHW-2-0350 350 35/w 95 mls .810 Inches 428 Lbs 280 Amps
    USE-RHH-RHW-2-0400 400 35/w 95 mls .850 Inches 482 Lbs 305 Amps
    USE-RHH-RHW-2-0500 500 35/w 95 mls .930 Inches 591 Lbs 350 Amps
    USE-RHH-RHW-2-0600 600 58/w 110 mls 1.035 Inches 715 Lbs 385 Amps
    USE-RHH-RHW-2-0700 700 58/w 110 mls 1.100 Inches 821 Lbs 375 Amps
    USE-RHH-RHW-2-0750 750 58/w 110 mls 1.130 Inches 873 Lbs 375 Amps
    USE-RHH-RHW-2-1000 1000 58/w 110 mls 1.280 Inches 1132 Lbs 500 Amps
      Results 1 - 18 of 18 1