American Wire Group - 175 MIL EPR 15 KV URD Cable<br>One Third Neutral<br>Aluminum Conductor
 Search Catalog
      GO   
 All Categories    175 MIL EPR 15 KV URD Cable
One Third Neutral
Aluminum Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > 
Primary URD Cable
15KV-35KV
 > 175 MIL EPR 15 KV URD Cable
100% Insulation Level
 > 175 MIL EPR 15 KV URD Cable
One Third Neutral
Aluminum Conductor
 > View Items 

    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

175 MIL EPR 15 KV URD Cable
One Third Neutral
Aluminum Conductor

Check up to five results to perform an action.

URD Cable

larger image

Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% insulation level.  Suitable for either direct burial or installation in ducts.

Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.

Standards
  • Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
  • Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
  • Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.




  • Request InformationCompare Items   Results per Page : 
      Results 1 - 10 of 10 1 

    Item #

    Conductor Size AWG

    Conductor Stranding

    Copper Neutral No. of Wires

    Copper Neutral Size AWG

    Diameters Conductor

    Diameter Over Insulation

    Diameter Over Insulation Shield

    Diameter Over Neutral Wires

    Diameter Over Embedded Jacket

    Total w/o Jacket Weight

    Total w/ Embedded Jacket Weight

    Ampacity 3/C Direct Buried

    Ampacity 3/C Triplex Buried

    Ampacity 3/C Duct In Air

    Conductor
    Type

    Max. Conductor Temp. (Normal Continuous)

    Max. Conductor Temp. (Overload)

    Max. Conductor Temp. (Short Circuit)

    175-EPR-10 1/0 Solid 6 14 0.325 Inches 0.735 Inches 0.815 Inches 0.943 Inches 1.043 Inches 471 Lbs 539 Lbs 230 Amps 165 Amps 145 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-11 1/0 19 6 14 0.370 Inches 0.770 Inches 0.840 Inches 0.970 Inches 1.070 Inches 482 Lbs 547 Lbs 230 Amps 165 Amps 145 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-12 2/0 19 7 14 0.420 Inches 0.820 Inches 0.880 Inches 0.010 Inches 1.110 Inches 552 Lbs 630 Lbs 250 Amps 190 Amps 167 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-13 3/0 19 9 14 0.470 Inches 0.870 Inches 0.930 Inches 0.100 Inches 1.200 Inches 630 Lbs 709 Lbs 280 Amps 215 Amps 189 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-14 4/0 19 11 14 0.530 Inches 0.930 Inches 0.990 Inches 0.130 Inches 1.230 Inches 737 Lbs 818 Lbs 320 Amps 245 Amps 215 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-15 250 37 13 14 0.570 Inches 0.990 Inches 1.050 Inches 0.170 Inches 1.270 Inches 849 Lbs 959 Lbs 345 Amps 270 Amps 237 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-16 350 37 11 12 0.680 Inches 1.090 Inches 1.190 Inches 0.360 Inches 1.460 Inches 1111 Lbs 1253 Lbs 405 Amps 325 Amps 285 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-17 500 37 16 12 0.810 Inches 1.220 Inches 1.330 Inches 1.490 Inches 1.590 Inches 1442 Lbs 1590 Lbs 460 Amps 385 Amps 338 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-18 750 61 15 10 0.990 Inches 1.410 Inches 1.520 Inches 1.720 Inches 1.890 Inches 1959 Lbs 2149 Lbs 515 Amps 475 Amps 417 Amps Aluminum 90 oC 130 oC 250 oC
    175-EPR-19 1000 61 20 10 1.140 Inches 1.570 Inches 1.710 Inches 1.920 Inches 2.030 Inches 2524 Lbs 2727 Lbs 565 Amps 540 Amps 475 Amps Aluminum 90 oC 130 oC 250 oC
      Results 1 - 10 of 10 1