American Wire Group - 220 MIL EPR 15 KV URD Cable
One Third Neutral
Copper Conductor
Search Catalog
By Keyword
By Item #
All Categories
220 MIL EPR 15 KV URD Cable
One Third Neutral
Copper Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Primary URD Cable
15KV-35KV
>
220 MIL EPR 15 KV URD Cable
133% Insulation Level
>
220 MIL EPR 15 KV URD Cable
One Third Neutral
Copper Conductor
>
View Items
Download PDF
Email This Page
Save To Favorites
220 MIL EPR 15 KV URD Cable
One Third Neutral
Copper Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 3/C Direct Buried
Ampacity 3/C Triplex Buried
Ampacity 3/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
220-EPR-26
1/0
19
9
14
0.370 Inches
0.870 Inches
0.930 Inches
1.080 Inches
1.181 Inches
825 Lbs
898 Lbs
290 Amps
210 Amps
185 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-27
2/0
19
11
14
0.420 Inches
0.910 Inches
0.980 Inches
1.100 Inches
1.207 Inches
967 Lbs
1054 Lbs
320 Amps
240 Amps
210 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-28
3/0
19
14
14
0.470 Inches
0.960 Inches
1.030 Inches
1.190 Inches
1.291 Inches
1134 Lbs
1223 Lbs
350 Amps
275 Amps
241 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-29
4/0
19
11
12
0.530 Inches
1.020 Inches
1.120 Inches
1.310 Inches
1.410 Inches
1393 Lbs
1486 Lbs
390 Amps
315 Amps
276 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-30
250
37
13
12
0.570 Inches
1.080 Inches
1.180 Inches
1.410 Inches
1.509 Inches
1616 Lbs
1730 Lbs
415 Amps
340 Amps
298 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-31
350
37
12
10
0.680 Inches
1.180 Inches
1.290 Inches
1.490 Inches
1.592 Inches
2130 Lbs
2280 Lbs
475 Amps
415 Amps
364 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-32
500
37
17
10
0.810 Inches
1.310 Inches
1.420 Inches
1.620 Inches
1.786 Inches
2825 Lbs
2985 Lbs
525 Amps
480 Amps
420 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-33
750
61
25
10
0.990 Inches
1.510 Inches
1.610 Inches
1.810 Inches
1.980 Inches
4058 Lbs
4263 Lbs
560 Amps
530 Amps
465 Amps
Copper
90
o
C
130
o
C
250
o
C
220-EPR-34
1000
61
33
10
1.140 Inches
1.660 Inches
1.810 Inches
2.010 Inches
2.175 Inches
5171 Lbs
5386 Lbs
600 Amps
590 Amps
518 Amps
Copper
90
o
C
130
o
C
250
o
C
Results 1 - 9 of 9