American Wire Group - 220 MIL EPR 15 KV URD Cable
Full Neutral
Aluminum Conductor
Search Catalog
By Keyword
By Item #
All Categories
220 MIL EPR 15 KV URD Cable
Full Neutral
Aluminum Conductor
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories
>
Primary URD Cable
15KV-35KV
>
220 MIL EPR 15 KV URD Cable
133% Insulation Level
>
220 MIL EPR 15 KV URD Cable
Full Neutral
Aluminum Conductor
>
View Items
Download PDF
Email This Page
Save To Favorites
220 MIL EPR 15 KV URD Cable
Full Neutral
Aluminum Conductor
Check up to five results to perform an action.
larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 9 of 9
1
Item #
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 1/C Direct Buried
Ampacity 1/C Duct Buried
Ampacity 1/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
220-EPR-01
2
Solid
10
14
0.258 Inches
0.760 Inches
0.840 Inches
0.968 Inches
1.068 Inches
518 Lbs
585 Lbs
170 Amps
115 Amps
100 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-02
2
7
10
14
0.290 Inches
0.780 Inches
0.840 Inches
0.970 Inches
1.075 Inches
534 Lbs
603 Lbs
170 Amps
115 Amps
100 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-03
1
Solid
13
14
0.289 Inches
0.790 Inches
0.870 Inches
0.998 Inches
1.098 Inches
587 Lbs
655 Lbs
195 Amps
140 Amps
123 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-04
1
19
13
14
0.330 Inches
0.830 Inches
0.890 Inches
1.020 Inches
1.121 Inches
606 Lbs
676 Lbs
195 Amps
140 Amps
123 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-05
1/0
Solid
16
14
0.325 Inches
0.825 Inches
0.905 Inches
1.033 Inches
1.133 Inches
665 Lbs
733 Lbs
230 Amps
155 Amps
135 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-06
1/0
19
16
14
0.370 Inches
0.870 Inches
0.930 Inches
1.060 Inches
1.161 Inches
691 Lbs
764 Lbs
230 Amps
155 Amps
135 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-07
2/0
19
13
12
0.420 Inches
0.910 Inches
0.980 Inches
1.100 Inches
1.207 Inches
808 Lbs
895 Lbs
270 Amps
185 Amps
162 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-08
3/0
19
16
12
0.470 Inches
0.960 Inches
1.030 Inches
1.190 Inches
1.291 Inches
926 Lbs
1015 Lbs
295 Amps
210 Amps
184 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-09
4/0
19
20
12
0.530 Inches
1.020 Inches
1.120 Inches
1.290 Inches
1.389 Inches
1135 Lbs
1228 Lbs
335 Amps
240 Amps
210 Amps
Aluminum
90
o
C
130
o
C
250
o
C
Results 1 - 9 of 9
1