larger image
Applications
For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 10 of 10
1
Item #
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 3/C Direct Buried
Ampacity 3/C Triplex Buried
Ampacity 3/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
220-EPR-10
1/0
Solid
6
14
0.325 Inches
0.825 Inches
0.905 Inches
1.033 Inches
1.133 Inches
541 Lbs
616 Lbs
230 Amps
165 Amps
145 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-11
1/0
19
6
14
0.370 Inches
0.870 Inches
0.930 Inches
1.060 Inches
1.161 Inches
558 Lbs
631 Lbs
230 Amps
165 Amps
145 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-12
2/0
19
7
14
0.420 Inches
0.910 Inches
0.980 Inches
1.100 Inches
1.207 Inches
628 Lbs
715 Lbs
250 Amps
190 Amps
167 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-13
3/0
19
9
14
0.470 Inches
0.960 Inches
1.030 Inches
1.190 Inches
1.291 Inches
708 Lbs
797 Lbs
280 Amps
215 Amps
189 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-14
4/0
19
11
14
0.530 Inches
1.020 Inches
1.120 Inches
1.270 Inches
1.369 Inches
863 Lbs
956 Lbs
320 Amps
245 Amps
215 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-15
250
37
13
14
0.570 Inches
1.080 Inches
1.180 Inches
1.370 Inches
1.469 Inches
978 Lbs
1092 Lbs
345 Amps
270 Amps
237 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-16
350
37
11
12
0.680 Inches
1.180 Inches
1.290 Inches
1.450 Inches
1.552 Inches
1219 Lbs
1369 Lbs
405 Amps
325 Amps
285 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-17
500
37
16
12
0.810 Inches
1.310 Inches
1.420 Inches
1.580 Inches
1.746 Inches
1555 Lbs
1715 Lbs
460 Amps
385 Amps
338 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-18
750
61
15
10
0.990 Inches
1.510 Inches
1.610 Inches
1.810 Inches
1.980 Inches
2144 Lbs
2349 Lbs
515 Amps
475 Amps
417 Amps
Aluminum
90
o
C
130
o
C
250
o
C
220-EPR-19
1000
61
20
10
1.140 Inches
1.660 Inches
1.810 Inches
2.010 Inches
2.175 Inches
2667 Lbs
2882 Lbs
565 Amps
540 Amps
475 Amps
Aluminum
90
o
C
130
o
C
250
o
C
Results 1 - 10 of 10