Applications
For use on single phase and three phase primary underground distribution systems operating at 25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts.
Construction
Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed.
Standards
Conforms to ICEA S-94-649 Std. for Concentric Neutral Cables Rated 5,000 - 46,000 V.
Conforms to ICEA S-97-682 Std. for Utility Shielded Power Cables Rated 5,000 - 46,000 V.
Conforms to AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV.
Results per Page :
25
50
100
200
Results 1 - 5 of 5
1
Item #
Conductor Size AWG
Conductor Stranding
Copper Neutral No. of Wires
Copper Neutral Size AWG
Diameters Conductor
Diameter Over Insulation
Diameter Over Insulation Shield
Diameter Over Neutral Wires
Diameter Over Embedded Jacket
Total w/o Jacket Weight
Total w/ Embedded Jacket Weight
Ampacity 1/C Direct Buried
Ampacity 1/C Duct Buried
Ampacity 1/C Duct In Air
Conductor
Type
Max. Conductor Temp. (Normal Continuous)
Max. Conductor Temp. (Overload)
Max. Conductor Temp. (Short Circuit)
260-EPR-18
1
19
13
12
0.330 Inches
0.910 Inches
0.970 Inches
1.100 Inches
1.200 Inches
951 Lbs
1032 Lbs
245 Amps
185 Amps
162 Amps
Copper
90
o
C
130
o
C
250
o
C
260-EPR-19
1/0
19
16
12
0.370 Inches
0.950 Inches
1.010 Inches
1.160 Inches
1.260 Inches
1107 Lbs
1190 Lbs
280 Amps
215 Amps
189 Amps
Copper
90
o
C
130
o
C
250
o
C
260-EPR-20
2/0
19
20
12
0.420 Inches
0.990 Inches
1.060 Inches
1.190 Inches
1.290 Inches
1320 Lbs
1420 Lbs
315 Amps
240 Amps
210 Amps
Copper
90
o
C
130
o
C
250
o
C
260-EPR-21
3/0
19
25
12
0.470 Inches
1.040 Inches
1.150 Inches
1.310 Inches
1.410 Inches
1588 Lbs
1691 Lbs
360 Amps
275 Amps
241 Amps
Copper
90
o
C
130
o
C
250
o
C
260-EPR-22
4/0
19
32
12
0.530 Inches
1.100 Inches
1.210 Inches
1.370 Inches
1.470 Inches
1927 Lbs
2034 Lbs
415 Amps
315 Amps
276 Amps
Copper
90
o
C
130
o
C
250
o
C
Results 1 - 5 of 5