American Wire Group - 8 AWG - 1000 MCM, FR-XLP, CPE Jacket, 600 Volts<BR><li>3/C w/Ground
 Search Catalog
      GO   
 All Categories    8 AWG - 1000 MCM, FR-XLP, CPE Jacket, 600 Volts
  • 3/C w/Ground
  • AWG CODE NAME FINDER
    Enter code name in the search field to the left for specific product information
    All Categories > Control Cable > FR-XLP/CPE Tray Cable
    Type TC, 600 Volt
     > 8 AWG - 1000 MCM, XLP/XHHW-2, CPE Jacket, 600 Volts
  • 3/C w/Ground > 8 AWG - 1000 MCM, FR-XLP, CPE Jacket, 600 Volts
  • 3/C w/Ground > View Items 
  •     Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites

    8 AWG - 1000 MCM, FR-XLP, CPE Jacket, 600 Volts
  • 3/C w/Ground
  • Check up to five results to perform an action.

    FR-XLPE  CPE 3 CONDUCTOR

    larger image
    Applications
    As flame-retardant three-conductor power cables rated 600 volts, 90 Deg. C. in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried.

    Construction
    Class B stranded uncoated copper conductor, FR-XLPE flame-retardant crosslinked polyethylene insulation, surface print phase identification. Three insulated conductors twisted with a Class B stranded uncoated copper grounding conductor and suitable fillers, cable tape, PVC jacket overall, surface printed.

    Standards
    1) Listed by UL as Type TC per Standard 1277 for Tray Cables.
    2) Individual conductors UL listed as Type XHHW-2.
    3) Individual conductors pass UL VW-1 flame test.
    4) Overall jacket UL listed as Sunlight Resistant and Oil Resistant II.
    5) Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hour test.
    6) Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test.
    7) Cables UL listed for Direct Burial.
    8) Cables UL listed for Open Wiring.
    9) Cables meet requirements of ICEA S-9568/NEMA WC70.

    Notes
  • AMPACITY in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature indicated, in wet or dry locations, 30oC ambient temperature.
  • Grounding conductor per UL Standard 1277 for Type TC Tray Cable.



  • Request InformationCompare Items   Results per Page : 
      Results 1 - 14 of 14 1 

    Item #

    No. of Conductors

    Size AWG or KCM

    Number
    of
    Strands

    Insulation Thickness
    (mls)

    Jacket Thickness
    (mls)

    Nominal Diameter Inches (mm)

    Grounding Conductor Size AWG

    Weight
    Per MFT

    Ampacity 90°C

    Ampacity 75°C

    3R-FRX-8 3 8 7 45 60 0.66 10 335 Lbs 55 Amps 50 Amps
    3R-FRX-6 3 6 7 45 60 0.74 8 475 Lbs 75 Amps 65 Amps
    3R-FRX-4 3 4 7 45 80 0.88 8 700 Lbs 95 Amps 85 Amps
    3R-FRX-2 3 2 7 45 80 1.00 6 1020 Lbs 130 Amps 115 Amps
    3R-FRX-1 3 1 19 55 80 1.13 6 1260 Lbs 150 Amps 130 Amps
    3R-FRX-1/0 3 1/0 19 55 80 1.22 6 1520 Lbs 170 Amps 150 Amps
    3R-FRX-2/0 3 2/0 19 55 80 1.31 6 1825 Lbs 195 Amps 175 Amps
    3R-FRX-3/0 3 3/0 19 55 80 1.42 4 2210 Lbs 225 Amps 200 Amps
    3R-FRX-4/0 3 4/0 19 55 80 1.55 4 2690 Lbs 260 Amps 230 Amps
    3R-FRX-250 3 250 37 65 110 1.76 4 3265 Lbs 290 Amps 255 Amps
    3R-FRX-350 3 350 37 65 110 1.98 3 4465 Lbs 350 Amps 310 Amps
    3R-FRX-500 3 500 37 65 110 2.26 2 6100 Lbs 430 Amps 380 Amps
    3R-FRX-750 3 750 61 80 110 2.71 1 6090 Lbs 535 Amps 475 Amps
    3R-FRX-1000 3 1000 61 80 140 3.10 1/0 11770 Lbs 615 Amps 545 Amps